Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
1.
Br J Med Med Res ; 2015; 10(8): 1-11
Article in English | IMSEAR | ID: sea-181779

ABSTRACT

Aim: The process of bone repair is of evident importance in both the clinical and functional spheres. For this reason, the field of bioengineering has taken it as an object of study, seeking to perfect the implantation of materials that allow for adequate bone neoformation. This study investigated the process of bone repair after anionic bovine tendon grafting in rat tibias by conducting a morphological, histomorphometric and immunohistochemical study. Methodology: The experimental model consisted of 36 rats randomly divided into two groups: a control group (CG, n=18), in which a surgical cavity in the tibia was filled with blood clots; and an experimental group (EG, n=18), in which a surgical cavity in the tibia was filled with an anionic bovine tendon graft. In the experimental group, the major axis of the collagen fiber bundle was placed perpendicularly to the long axis of the tibia. Microscopic, morphometric and immunohistochemical evaluations were conducted at 7, 15, and 30 days postoperative. Results: The analyzes showed an increase in bone neoformation in the experimental group during the assessed periods. There was a significant difference between day 7 and day 30 and evident vascular proliferation was detected by the immunohistochemical analysis. Conclusion: It can be concluded that the anionic bovine tendon collagen proved to be an adequate and biocompatible material for bone regeneration, with osteogenic capabilities that allow it to be used as a scaffold for bone repair.

2.
Rev. bras. cir. cardiovasc ; 29(2): 249-254, Apr-Jun/2014. tab, graf
Article in Portuguese | LILACS | ID: lil-719408

ABSTRACT

O paradoxo do cálcio foi pela primeira vez citado em 1966 por Zimmerman et al. A partir daí, ganhou grande interesse por parte da comunidade científica internacional devido ao fato da ausência do íon cálcio produzir na célula muscular cardíaca dano semelhante à lesão de isquemia-reperfusão. Apesar de não serem conhecidos todos os mecanismos envolvidos no processo da lesão celular no paradoxo do cálcio, a conexão intercelular mantida somente pelo nexus parece ter papel chave na fragmentação celular. A adição de pequenas concentrações de cálcio, bloqueadores de canal de cálcio, hiponatremia ou hipotermia são importantes para evitar que haja lesão celular no momento da reperfusão com soluções com concentração fisiológica de cálcio.


The calcium paradox was first mentioned in 1966 by Zimmerman et al. Thereafter gained great interest from the scientific community due to the fact of the absence of calcium ions in heart muscle cells produce damage similar to ischemia-reperfusion. Although not all known mechanisms involved in cellular injury in the calcium paradox intercellular connection maintained only by nexus seems to have a key role in cellular fragmentation. The addition of small concentrations of calcium, calcium channel blockers, and hyponatraemia hypothermia are important to prevent any cellular damage during reperfusion solutions with physiological concentration of calcium.


Subject(s)
Animals , Humans , Rats , Calcium/metabolism , Heart Injuries/metabolism , Myocytes, Cardiac/metabolism , Adenosine Triphosphate/metabolism , Cell Membrane Permeability , Caffeine/adverse effects , Calcium Channel Blockers/pharmacology , Calcium/administration & dosage , Dinitrophenols/metabolism , Glycocalyx/metabolism , Heart Failure/etiology , Heart Injuries/etiology , Heart Injuries/pathology , Myocardial Reperfusion Injury/metabolism , Myocardium/metabolism , Sodium/physiology , Time Factors
3.
Rev. odonto ciênc ; 23(2): 134-140, abr.-jun. 2008. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: biblio-873603

ABSTRACT

Objetivo: Este trabalho teve por objetivo preparar e caracterizar um novo compósito de colágeno com silicato e hidroxiapatita que possa vir a ser utilizado como material endodôntico em capeamento pulpar direto e em pulpotomia. Metodologia: Os materiais utilizados como matéria-prima foram colágeno do tipo I na forma aniônica, silicato (cimento Portland Branco) e hidroxiapatita sintetizada. Estes materiais foram misturados em proporções variadas de modo a obter um material compósito na forma de pasta. Os materiais obtidos foram caracterizados por técnicas de calorimetria exploratória diferencial, termogravimetria, microscopia eletrônica de varredura (MEV), espectrometria de dispersão de energia de Raios-X e espectroscopia na região do infravermelho.Resultados: A presença de colágeno no compósito foi demonstrada por transições térmicas típicas daquelas encontradas para o colágeno do tipo I (-48ºC), independentemente da proporção utilizada, e também por imagens de MEV, onde as fibras colagênicas também puderam ser observadas interligando as partículas de silicato. A composição química de todos compósitos de colágeno foi praticamente idêntica à do silicato utilizado.Conclusão: Os resultados mostraram que a estrutura da matriz de colágeno nos compósitos testados não foi alterada. Esta é uma característica importante para a utilização em endodontia do material compósito proposto, objetivando uma reparação tecidual de forma 'mais natural'.


Purpose: This study aimed to prepare and characterize a new collagen composite with silicate and hydroxyapatite as a potential endodontic material for pulp capping and pulpotomy. Methods: Anionic type I collagen was mixed with silicate (White Portland cement) and hydroxyapatite in several proportions. The materials were characterized by standard differential scanning calorimetry, thermogravimetry, scanning electron microscopy (SEM), energy dispersion x-ray, and infrared spectrometry. Results: The presence of collagen in the composite was observed by means of typical thermal transitions for collagen type I (-48ºC), independently from the proportion used. SEM images showed collagen fibers interconnecting silicate particles. The chemical composition of all collagen composites was essentially the same as that of the original silicate. Conclusion: These results showed that the collagen matrix structure of the tested composite was not altered, which is an important feature for a 'more natural' tissue repair in Endodontics.


Subject(s)
Collagen , Composite Resins , Dental Pulp Capping , Durapatite , Dental Materials/therapeutic use , Silicates
4.
Ciênc. odontol. bras ; 10(3): 12-20, jul.-set. 2007. ilus
Article in English | LILACS, BBO | ID: lil-500843

ABSTRACT

This study aimed to analyze the biocompatibility of anionic collagen matrices, the local bone response following implantation in surgically-created bone defects, and also the influence of the collagen fiber orientation on the neoformed osseous tissue. Seventy two rats (Rattus norvegicus albinus) were used in this experiment. The animals were divided into four experimental groups: Group 1 (control), without implants; Group 2, pericardium medullar implants 12 hours; Group 3, medullar implants of tendon 24 hours, with the long axis of collagen fibers oriented parallel to the long axis of the tibia; and Group 4, medullar implants of tendon 24 hours, with the long axis of collagen fibers perpendicular to the long axis of the tibia. After the experimental surgery, the evolution of the repair process was microscopically evaluated at 7, 15, and 30 days post-surgery. The results demonstrated that the implanted matrices are biocompatible and act as a scaffold inducing bone formation, mainly in the Group 4 animals. At first, cellularity follows the arrangement of collagen fibers, later obtaining a multidirectional growth.


Este estudo apresentou como objetivo, examinar a biocompatibilidade de matrizes de colágeno aniônico, sua respostaóssea local após implantação em defeitos ósseos criados cirurgicamente e a influência da orientação das fibras colágenasno tecido ósseo neoformado. Foram utilizados 72 ratos (Rattus norvegicus albinus) divididos em 4 grupos experimentaisde 6 animais cada: Grupo 1 (Controle), sem implante; Grupo 2, implante medular de pericárdio 12 horas; Grupo 3,implante medular de tendão 24 horas, com o maior eixo de suas fibras colágenas direcionados paralelamente ao maioreixo da tíbia e, Grupo 4, implante medular de tendão 24 horas, com o maior eixo de suas fibras colágenas direcionados perpendicularmente ao maior eixo da tíbia. A evolução do processo de reparo, após a cirurgia experimental, foi avaliada microscopicamente com 7, 15 e 30 dias pós-operatórios. Os resultados demonstraram que as matrizes implantadas são biocompatíveis e funcionam como uma matriz tridimensional induzindo a formação de osso, maior no grupo 4. A celularidade, inicialmente, acompanha o arranjo das fibras colágenas, adquirindo um arranjo multidirecional crescente.


Subject(s)
Animals , Rats , Collagen , Biocompatible Materials , Osteogenesis , Bone Regeneration
5.
Rev. bras. cir. cardiovasc ; 20(1): 14-22, Jan.-Mar. 2005. ilus
Article in Portuguese | LILACS | ID: lil-413202

ABSTRACT

Objetivo: Neste estudo, tivemos como objetivo comparar a resistência mecânica do pericárdio decelularizado com o pericárdio convencional, assim como avaliar sua capacidade de induzir resposta inflamatória em modelo experimental com ratos.Método: Dividimos os pericárdios em: GrupoI - pericárdio submetido a tratamento convencional. Após o processamento químico, as amostras do GrupoII foram histologicamente avaliadas para confirmar a eficácia da decelularização. A seguir, apenas para análise da resistência mecânica por testes de tração e de desnaturação térmica, os pericárdios foram divididos em: grupo 1 (pericárdio convencional com critérios de aprovação), grupo 2(pericárdio convencional com critérios de reprovação) e grupo 3(pericárdio decelularizado). A capacidade de induzir resposta inflamatória foi avaliada em estudo experimental em 50 ratos Wistar, os quais foram submetidos a implante subcutâneo d fragmentos dos pericárdios. Nossa terceira etapa de avaliação consistiu em confeccionar três biopróteses com o pericárdio decelularizado e que foram submetidas à avaliação hidrodinâmica, juntamente com uma bioprótese convencional de teste.Resultados: A análise histológica inicial demostrou decelularização completa. A resistência mecânica mostrou diferença significativa com relação às variáveis "tensão de ruptura" e "índice de tenacidade". Não encontramos diferença quanto a atividade inflamatória em modelo experimental com ratos. O desempenho hidrodinâmico foi semelhante e todas biopróteses atingiram a marca de 150 milhões de ciclos. A avaliação histológica ao fim da ciclagem mostrou padrão microscópico habitual, não havendo ruptura ou fragmentação anormal induzida por estresse mecânico.Conclusão: A decelularização mantém a resistência física do pericárdio, além de não induzir resposta inflamatória diferente daquela habitualmente encontrada no pericárdio convencional


Subject(s)
Animals , Bioprosthesis/trends , Bioprosthesis , Heart Valve Prosthesis , Pericardium/surgery , Pericardium/physiopathology , Technology Assessment, Biomedical/trends , Technology Assessment, Biomedical
6.
Rev. bras. eng. biomed ; 19(3): 167-173, dez. 2003. ilus
Article in English | LILACS | ID: lil-417957

ABSTRACT

Uma alternativa para o transplante de tecido e órgãos ou para a substituição de funções biológicas é a engenharia de tecido, baseada no crescimento de células isoladas em matrizes tridimensionais biodegradáveis. Este trabalho descreve a preparação, a caracterização e o comportamento de matrizes polianiônicas de colágeno:elastina preparadas a partir de pericárdio bovino nativo e implantadas no subcutâneo de ratos. Os resultados mostraram que estes materiais correspondem a matrizes acelulares polianiônicas de colágeno:elastina formadas por fibras colágenas preservadas. Em comparação ao pericárdio nativo, a resposta biológica foi caracterizada pelo decréscimo progressivo da resposta inflamatória, e, praticamente, não existindo para o material com elevados grupos de carboxila, sugerindo alto grau de biocompatibilidade destas matrizes acelulares de colágeno:elastina. Os resultados mostram também evidências da incorporação do material pelo tecido adjacente, sugerindo que as matrizes polianiônicas de colágeno:elastina podem ser de uso potencial na engenharia de tecido


Subject(s)
Elastin , Histocompatibility , Collagen/therapeutic use , Extracellular Matrix Proteins/therapeutic use , Transplants , Histological Techniques/methods , Histological Techniques/trends
7.
Rev. bras. eng. biomed ; 18(1): 7-16, jan.-abr. 2002. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-358863

ABSTRACT

Este trabalho descreve a preparação e a caracterização de compósitos de colágeno aniônico:ramsana, com o propósito de desenvolver géis injetáveis para correções plásticas. Os materiais foram caracterizados por eletroforese, espectroscopia no infravermelho, estabilidade térmica, titulação potenciométrica, propriedades reológicas e ensaios de fluidez. Independentemente do processamento, os materiais estudados são formados por colágeno não desnaturado, com um total de grupos carboxílicos de 345,9 ± 9/mol de colágeno, o que representa a pH fisiológico um excedente de 106 ± 17 cargas negativas em relação ao colágeno nativo. O estudo reológico mostrou que: independentemente do pH, géis de colágeno aniônico e seus compósitos com ramsana apresentaram o módulo de armazenamento sempre maior que o módulo de perda (G' > G" e delta <45 graus); géis colégeno aniônico:ramsana equilibrados a pH 7,4, embora menos elásticos que os géis equilibrados a pH 3,5; géis contendo ramsana foram mais susceptíveis à deformação; a força necessária para o escoamento de géis contendo ramsana foi sempre significativamente menor que aquela determinada para o colágeno aniônico e com um perfil mais limpo em relação à presença de picos de contrapressão, sugerindo que a associação colágeno aniônico:ramsana pode substituir com vantagens o glutaraldeído na estabilização das preparações comerciais do gel. Os resultados de biocompatibilidade de géis de CAR injetados na membrana vesical de coelho mostraram que estes compósitos são compatíveis com a sua utilização em correções plásticas.


Subject(s)
Bioprosthesis/trends , Bioprosthesis , Surgery, Plastic/trends , Collagen/therapeutic use , Biocompatible Materials/therapeutic use , Gels/therapeutic use , Rheology
8.
Braz. dent. j ; 12(3): 209-213, set.-dez. 2001. tab, CD-ROM
Article in English | LILACS, BBO | ID: biblio-872591

ABSTRACT

Este estudo avaliou o efeito de irrigação subgengival de gel colágeno com clorexidina 1 por cento em bolsas periodontais como adjunto à raspagem e alisamento radicular (RAR). Participaram do estudo em 6 pacientes com periodontite periodontal crônica (37 sítios) que apresentavam sítios com profundidade de sondagem entre 5-7 mm e BANA positivos. Foi realizado o tratamento de RAR em todos os sítios, sendo estes distribuídos em um dos 3 grupos: somente RAR (grupo I), RAR + irrigação com gel de colágeno (grupo II), RAR + irrigação com gel de colágeno com clorexidina 1 por cento (grupo III). As irrigações subgengivais foram realizadas após a RAR e nos dias 7, 14 e 21. Os parâmetros clínicos de índice de placa, índice gengival, sangramento à sondagem, nível de inserção, recessão e profundidade de sondagem foram avaliados antes da raspagem 60 e 90 dias após, e o Teste BANA (PERIOSCAN) foi realizado com as amostras de placa dos mesmos sítios, antes da raspagem e 90 dias após. Os resultados obtidos demonstraram uma redução dos parâmetros clínicos sem diferença significante entre os três grupos, com exceção dos parâmetros de índice gengival e sangramento à sondagem onde os resultados foram estatisticamente melhores no grupo III que nos grupos I e II. Os grupos I e II apresentaram redução estatisticamente maior dos sítios BANA positivos quando comparados ao grupo I. Os resultados sugerem que a irrigação subgengival com gel colágeno com clorexidina 1 por cento mostrou-se promissora como coadjuvante ao tratamento de RAR em pacientes com doença periodontal crônica


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Chlorhexidine , Collagen/administration & dosage , Periodontal Pocket , Dental Plaque Index , Dental Scaling , Gels , Therapeutic Irrigation , Periodontal Index , Gingival Recession/therapy
9.
Braz. dent. j ; 12(1): 9-15, jan.-jun. 2001. ilus
Article in English | LILACS, BBO | ID: lil-554370

ABSTRACT

The authors studied the behaviour of calcium phosphate materials used as inlay implants into bone cavities prepared in the zygomatic arch of rats. Fifty male albino rats were divided into four groups as follows: Group I - preparation of bone cavities which did not receive any implant material as controls; Group II - implants of Interpore© 200; Group III - implants of experimental hydroxylapatite; Group IV - implants of experimental hydroxilapatite combined whith collagen. The animals were sacrificed after 5, 15, 30, 60 and 120 days and specimens were submitted to histological analysis. Results showed that experimental hydroxylapatite used in group III presented better osteogenic properties compared to the other materials. All tested materials were biocompatible, although group IV presented a more intense inflammatory response.


Subject(s)
Animals , Rats , Durapatite , Zygoma , Biocompatible Materials , Collagen/pharmacokinetics , Implants, Experimental
10.
Rev. odontol. UNESP ; 28(2): 345-58, jul.-dez. 1999. ilus
Article in Portuguese | LILACS, BBO | ID: lil-298421

ABSTRACT

O presente estudo avaliou histologicamente o comportamento biológico de um composto experimental de hidroxiapatita-colágeno implantado em posiçäo subperiosteal em calotas cranianas de ratos. Cinco animais foram sacrificados para cada período experimental, aos 5, 15, 30, 60 e 120 dias de pós-operatório, sendo obtidos cortes semi-seriados dos espécimes para exame histológico. Os resultados demonstraram que o material estudado é biocompatível e sofre reabsorçäo intensa. Nos períodos tardios, os grânulos de hidroxiapatita do composto apresentaram-se cercados por osteoblastos que aparentemente depositavam matriz orgânica em sua superfície


Subject(s)
Animals , Rats , Hydroxyapatites , Collagen , Biocompatible Materials/analysis
11.
Rev. odontol. UNESP ; 28(1): 83-96, jan.-jun. 1999. ilus
Article in Portuguese | LILACS, BBO | ID: lil-271339

ABSTRACT

O objetivo deste trabalho foi estudar histopatologicamente o comportamento de uma hidroxiapatita implantada em alvéolos dentais de ratos. Para tanto, foram utilizados 40 ratos machos (Rattus norvegicus, albinus, Holtzman) divididos em dois grupos que, após exodontia do incisivo superior direito, receberam o seguinte tratamento: grupo G1, controle (näo tratado), e grupo G2, implante de hidroxiapatita particulada (64 µm). Os animais de cada condiçäo experimental foram sacrificados em grupos de quatro aos 4, 7, 15, 24 e 60 dias pós-operatórios, sendo os espécimes submetidos à tramitaçäo laboratorial de rotina para análise histopatológica. Os resultados mostraram que a hidroxiapatita testada produziu um atraso na cronologia do processo de reparo alveolar em comparaçäo aos animais controle, uma vez que menos tecido ósseo foi formado ao longo de todos os períodos. Além disso, o material utilizado apresentou compatibilidade biológica, pois foi integrado pelos tecidos ao longo do processo de reparo


Subject(s)
Animals , Rats , Hydroxyapatites/analysis , Dental Implants , Biocompatible Materials
12.
Rev. odontol. UNESP ; 25(n.esp): 65-75, jan.-dez. 1996. ilus
Article in Portuguese | LILACS, BBO | ID: lil-197493

ABSTRACT

O propósito deste estudo foi avaliar o comportamento tecidual de uma membrana experimental de colágeno bovino, em periodonto de cäes, seu padräo de rea


Subject(s)
Animals , Dogs , Collagen/analysis , Biocompatible Materials/analysis , Guided Tissue Regeneration
13.
Rev. odontol. UNESP ; 25(n.esp): 145-55, jan.-dez. 1996. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-197500

ABSTRACT

O objetivo deste estudo foi avaliar histologicamente, em cäes, a efetividade de uma membrana de colágeno bovino reticulado, no tratamento de defeitos ósseos periimplantares do tipo deiscência. Foram extraídos os pré-molares inferiores de dois cäes. Após 12 semanas foram confeccionados quatro sítios para colocaçäo de implantes osseointegrados, com uma deiscência óssea vestibular de 5 mm de altura e 3 mm de largura, de cada lado dos dois cäes, com um total de 16 implantes. Metade dos implantes foi coberta com uma membrana de colágeno bovino reticulado (Grupo Teste), enquanto a outra näo recebeu nenhuma membrana (Grupo Controle). Três implantes foram perdidos (um do Grupo Teste e dois do Grupo Controle). Após o período de 12 semanas, os animais foram sacrificados. A análise histométrica foi realizada com o auxílio de um Sistema de Análise de Imagem Computadorizado. Os dados obtidos foram analisados por meio do teste t de Student, revelando uma diferença estatisticamente significativa para as medidas de altura (teste = 2,34 mm e controle = 1,17 mm; p = 0,002) e área (teste = 1,82mm2 e controle = 0,70 mm2; p= 0,006). O estudo demonstrou que a membrana do colágeno favoreceu a formaçäo óssea em defeitos periimplantares, tipo deiscência, em relaçäo ao Grupo Controle


Subject(s)
Animals , Dogs , Collagen , Dental Implants , Biocompatible Materials/analysis , Bone Regeneration , Bicuspid/surgery , Tooth Extraction
14.
Rev. bras. cir. cardiovasc ; 11(4): 270-3, out.-dez. 1996. tab, graf
Article in Portuguese | LILACS | ID: lil-184577

ABSTRACT

A maioria dos implantes valvulares cardíacos realizados no Brasil é representada pelas válvulas de pericárdio bovino, seguidas por próteses porcinas. Na avaliaçao de válvulas biológicas, deve-se considerar: desempenho hidrodinâmico, resistência à fadiga e processo de calcificaçao. No presente estudo, foi avaliado o desempenho hidrodinâmico de biopróteses de pericárdio bovino (Biopro-PB-Braile Biomédica) comparativamente às válvulas porcinas (Biopro-PP-Braile Biomédica) através do gradiente médio transvalvular. Os testes hidrodinâmicos foram realizados em próteses de diâmetros variando de l9 a 35 mm, submetidas ao Sistema Duplicador de Pulsos Shelhigh (Shelhigh Inc.). O volume de ejeçao foi mantido constante em 90 ml, com freqüência de pulso de 60, 70, 80, 90 e l00 ciclos por minuto, possibilitando fluxos entre 5 e 9 litros por minuto, equivalentes a fluxos contínuos aproximados de 8 a 18 litros por minuto. Houve tendência à diminuiçao dos gradientes pressóricos à medida em que aumenta o diâmetro externo das próteses. O gradiente pressórico médio encontrado em próteses de pericárdio bovino foi significativamente menor que o de próteses porcinas (p

Subject(s)
Humans , Animals , Bioprosthesis , Cattle , Heart Valve Prosthesis , Materials Testing , Pericardium , Swine , Analysis of Variance , Hydrodynamics
15.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.41-42, graf.
Monography in Portuguese | LILACS | ID: lil-236236

ABSTRACT

Este trabalho estudou a liberação controlada dos antibióticos rolitetraciclina e ciprofloxacina suportados em membranas de colágeno. No caso de membranas com ciprofloxacina, ocorreu liberação total em 10 min, enquanto que a liberação da rolitetraciclina ocorreu durante um período de 90 min, com valores de k e n de respectivamente 0,10 e 0,48, por meio de um processo de difusão comum. Estes resultados sugerem que a rolitetraciclina suportada pode ser utilizada em periodontia e em implantes dentários.


Abstract: This work studied the controlled release of rolitetracycline and ciprofloxacine supported by collagen membranes. While ciprofloxacine was totally released within a time interval of 1 O min, rolitetracycline was released to only 73% after 90 min, with values for k and n of respectively O, 1 O and 0,48, suggesting a normal diffusion release mechanism. These results suggest that supported rolitetracyclines may be useful with periodontal and dental implant surgery


Subject(s)
Anti-Bacterial Agents/pharmacokinetics , Collagen , Rolitetracycline/pharmacokinetics , Ciprofloxacin/pharmacokinetics , Polymers
16.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.43-44, tab, graf.
Monography in Portuguese | LILACS | ID: lil-236237

ABSTRACT

Este trabalho estudou a hidrólise alcalina seletiva dos resíduos de glutamina e asparagina de colágeno para obtenção de colágeno aniônico. As caracterizações foram realizadas por titulação potenciométrica e calorimetria exploratória diferencial, mostraram que este tratamento hidrolisou seletivamente os grupos carboxamidos presentes no colágeno, sem prejuízo das ligações peptidicas ou estrutura secundária da proteína. Estes materiais mostraram um coeficiente piroelétrico de 1.16 x 10(-4) Cm(-2), maior que o encontrado para o PVDF polarizado, de 7X10(-6 Cm(-2).


Abstract: This work studied the selective alkaline hydrolysis of glutamine and asparagine residues of collagen in order to produce anionic collagen. Characterization of the hydrolysed material by potenciometric titration and differential scanning calorimetry, showed that the selective hydrolysis was achieved, without unpairing both, the peptide bond or the native protein structure. The piroelectric coefficient determined for this material was l. l 6x 1 o-" Cm-2 · is in comparison to 7x 10-6 Cm-2 for polarized PVDF


Subject(s)
Asparagine , Glutamine , Collagen , Hydrolysis , Biocompatible Materials
17.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.45-46, graf.
Monography in Portuguese | LILACS | ID: lil-236238

ABSTRACT

Este trabalho estuda o uso de géis injetáveis de colágeno-ramsana como veículo de liberação controlada de digluconato de clorexidina. Estudos de liberação mostraram que a presença do polissacarídeo reduz a quantidade de droga liberada no mesmo período de tempo, quando comparada com a taxa de liberação no gel normal. A análise do tipo de liberação pela expressão: M(1)/M(0) = Kt(n), mostraram que a presença de ramsana no gel reduz o coeficiente de difusão da clorexidina. Os valores obtidos para n sugerem que, para todos os géis, a cinética de difusão da droga é anômala.


Abstract - This work repo11s the use of injectable collagen:rhamsan gels as vehicles for drug delivery of chlorhexidine. Release results showed that the presence of rhamsan significantly inhibits drug release due to a reduction in the diffusion coefficient as deterrnined by the equation M/M0 kt 11• Values of n suggests that the mechanisrn of sustained drug delivery follows an anomalous diffusion kinetics


Subject(s)
Chlorhexidine/pharmacokinetics , Collagen/administration & dosage , Gels , Injections
18.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.47-48, graf.
Monography in Portuguese | LILACS | ID: lil-236239

ABSTRACT

Este trabalho estudou o comportamento de soluções de glutaraldeído utilizadas na fixação de biopróteses, por meio das relações 280/235 nm. Os resultados mostraram que este índice de controle analítico não é adequado, porque grandes variações nesta relação são devidas aos elevados valores de coeficientes de extinção molares das formas poliméricas. Foram detectadas também variações significativas nas absorbâncias em 280nm, sugerindo a ocorrência de alterações químicas do glutaraldeído em função do tempo (< 7 dias). Estes resultados mostram que estas soluções de glutaraldeído podem estar longe do ideal a obtenção de biopróteses homogêneas.


Abstract - This work studied the behavior of aqueous or buffered glutaraldehyde solutions used for the fixation of cardiac bioprostheses by means of the 280/235 nm ratios. The results showed that this analytical index may not be adequate since great variations are mainly due to the high extinction coefficients for the polymeric forms. Besides, variations were also observed in the 280 nm absorbancies, suggesting that significative changes may also occur in glutaraldehyde effective concentration (7 days). These results suggests that this type of glutaraldehyde solutions may be far from ideal for the manufacture of homogeneou


Subject(s)
Heart Valve Prosthesis , Glutaral , Bioprosthesis , Spectrophotometry, Infrared
19.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.49-50, graf.
Monography in Portuguese | LILACS | ID: lil-236240

ABSTRACT

Um Gel injetável de colágeno: ramasana (75:1) foi estudado como suporte para liberação de antibióticos para o tratamento de doenças periodontais. Os resultados mostraram que nas condições estudadas e na presença do antibiótico rolitetraciclina, a liberação ocorreu por meio de um processo difusional normal, com um valor de n igual a 0,47 + 0,02. A liberação sustentada se manteve por um período de 10 dias, com uma taxa de liberação de cerca de 90 por cento nesse período, tempo compatível para o controle da flora bacteriana junto ao periodonto.


Subject(s)
Rolitetracycline/pharmacokinetics , Collagen/administration & dosage , Gels/administration & dosage , Periodontal Diseases/metabolism , Periodontal Diseases/drug therapy , Injections
20.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.125-126, ilus.
Monography in Portuguese | LILACS | ID: lil-236278

ABSTRACT

No presente estudo foi avaliada a performance hidrodinâmica de bioprótese de pericárdio bovino comparativamente às válvulas porcinas, ambas produzidas no Brasil. Os testes hidrodinâmicos foram realizados em próteses de diâmetros variando de 19 a 35 mm em um sistema duplicador de pulso. O gradiente pressórico médio das próteses de pericárdio bovino foi significativamente menor que o de prótese porcinas (p<0,01) para todos os diâmetros estudados.


Abstract - ln the present study hydrodynamic performance of bioprostheses of bovine pericardium and procine valve were evaluated. The hydrodynamic test were performed in a pulse duplicator system using valves of different diameters from 19 to 35 mm. Pressure gradients measured in bovine pericardium prostheses were significantly (p<0.01) lower than those of porcine valves for all studied valve diameter


Subject(s)
Animals , Pericardium/surgery , Cattle , Bioprosthesis , In Vitro Techniques , Swine , Materials Testing , Heart Valve Prosthesis , Hydrodynamics
SELECTION OF CITATIONS
SEARCH DETAIL